Technology of lasic laser


The LASIK technique was made possible by the Colombia-based Spanish ophthalmologist Jose Barraquer, who, around 1950 in his clinic in Bogotá, Colombia, developed the first microkeratome, used to cut thin flaps in the cornea and alter its shape, in a procedure called keratomileusis. Stephan Schaller assisted. Barraquer also provided the knowledge about how much of the cornea had to be left unaltered to provide stable long-term results.

Later technical and procedural developments included the RK (radial keratotomy), started in the '70s in Russia by Svyatoslav Fyodorov , and the development of PRK (photorefractive keratectomy) in the '80s in Germany by Theo Seiler. RK is a procedure where radial corneal cuts are made typically using a micrometer diamond knife, and has nothing to do with LASIK

In 1968, at the Northrup Corporation Research and Technology Center of the University of California, Mani Lal Bhaumik and a group of other scientists, while working on the development of a carbon-dioxide laser, developed the Excimer laser. This formed the cornerstone for LASIK eye surgery. Dr. Bhaumik announced his discovery in May of 1973 at a meeting of the Denver Optical Society of America in Denver, Colorado. He would later patent it.

The introduction of Laser in this refractive procedure started with the developments in Laser technology by Rangaswamy Srinivasan. In 1980, Srinivasan, working at IBM Research Lab, discovered that an ultraviolet excimer laser could etch living tissue in a precise manner with no thermal damage to the surrounding area. He named the phenomenon Ablative Photodecomposition (APD).[2]. Dr. Stephen Trokel published a paper in the American Journal of Ophthalmology in 1983, outlining the potential of using the excimer laser in refractive surgeries.

The first patent for LASIK was granted by the US Patent Office to Gholam A. Peyman, MD on June 20, 1989, US Patent #4,840,175, "METHOD FOR MODIFYING CORNEAL CURVATURE", describing the surgical procedure in which a flap is cut in the cornea and pulled back to expose the corneal bed. This exposed surface is then ablated to the desired shape with an excimer laser, following which the flap is replaced.

Using these advances in laser technology and the technical and theoretical developments in refractive surgery made since the 50's, LASIK surgery was developed in 1990 by Lucio Buratto (Italy) and Ioannis Pallikaris (Greece) as a melding of two prior techniques, keratomileusis and photorefractive keratectomy. It quickly became popular because of its greater precision and lower frequency of complications in comparison with these former two techniques.

Today, faster lasers, larger spot areas, bladeless flap incision, intraoperative pachymetry, and wavefront-optimized and -guided techniques have significantly improved the reliability of the procedure compared to that of 1991. Nonetheless, the fundamental limitations of excimer lasers and undesirable destruction of the eye's nerves have spawned research into many alternatives to "plain" LASIK, including all-femtosecond correction (Femtosecond Lenticule EXtraction, FLIVC), LASEK, Epi-LASIK, sub-Bowman’s Keratomileusis aka thin-flap LASIK, wavefront-guided PRK, and modern intraocular lenses.

RETREATMENTS

Examples of healing and ablation related complications are:
Topographical abnormalities: decentrations, central islands, and peninsulas
Spherical aberrations: night vision problems, night glare, halos, star-bursting, ghosting
Irregular astigmatism: loss of best corrected spectacle vision
There is of course considerable cross-over as many surgically induced complications produce loss of contrast sensitivity, loss of best corrected vision and severe disturbances in night vision. While we have been managing surgical complications for several years, the development of wavefront technology has allowed us to finally fully evaluate all these patients and present possible treatment options for them. In about 70% of cases, we are now able to provide topographically guided solutions for patients. It is impossible however to predict which patients will be the most suitable candidates with the best chance of success until completing the diagnostic wavefront and topographical testing. The WaveLight 500 Hz Concerto Laser has been our excimer laser system of choice as the Tscherning wavefront analysis system has provided us with reproducible detailed data in the majority of cases for surgical planning. The laser system also possesses specific features ideal for both the new patient and the post-refractive surgery patient for higher quality visual results:
Laser spot size < 0.90 mm [0.63 mm half max.] Repetition rate 400 Hz True Effective Optical Zones upto 7 mm Infrared Eye-tracker with 2.5 msec response time and automatic centration Prolate cornea ( aspheric treatment patterns for classic and wavefront applications) The small laser spot size is mandatory to produce fine complex treatment patterns. The rapid repetition rate is vital to maintain corneal hydration intra-operatively, especially in wavefront guided procedures with larger optical zones where a prolonged treatment time could adversely affect the planned treatment profile. A simple principle in laser refractive surgery is to keep the eye as physiologically hydrated as possible intra-operatively for a faster visual recovery with less risk of swelling and epithelial ingrowth. In cases of patients with night glare, the ability to create a prolate 7 mm true effective optical zone with a 9mm blend zone is highly beneficial. Lastly, the eye-tracking response time must be short enough to adequately account for saccadic eye movement. The Wavelight Allegretto response time is better than any other excimer laser system without the need to dilate the pupil, which allows the patient to fixate on the target light more easily with a faster visual recovery. For topography-linked retreatments, the WaveLight 500 Hz Concerto Laser has the best capabilities at present. It should be understood however that the diagnostic analysis is what determines the final treatment method of choice recommended to any individual patient.

Safety

The WaveLight 500 Hz Concerto Laser is a laser that provides the doctor and the patient the highest level of safety, accuracy and reliability in LASIK, allowing the doctor to truly customize and offer a treatment that is ideally adjusted to the individual needs of the patient.
The WaveLight 500 Hz Concerto Laser saves upto 40% of valuable corneal tissue for every dioptre of treatment when compared with other lasers. This results in the doctor being able to treat a higher power range keeping in mind long-term safety as well as treating lower powers with unmatched stability.

Procedure



This is an outpatient procedure that usually takes 5-10 minutes per eye. The actual laser treatment usually takes a few seconds. First you will lie on the motorized bed. The eyes are anesthetized with eye drops only. The head is positioned under the laser. A soft clip keeps the eyelids gently and comfortably open during the treatment. You will be asked to look at a soothing green blinking light during the entire procedure.
During the treatment, an instrument called the microkeratome creates a corneal flap to make it a painless procedure. The computerized Excimer laser uses a beam of light to gently reshape the cornea so as to alter its curvature to the desired extent. The flap when replaced on the new corneal curvature allows images to be sharply focused on the retina. The goal is to eliminate or greatly reduce the dependence on glasses or contact lenses.
Once the procedure is completed, a soft contact lens or shield is sometimes placed on the eye. A post - procedure eye examination is performed and eye drops are prescribed. There may be mild discomfort for a few hours after the procedure.

INTRODUCTION


LASIK eye surgery has become the most popular refractive procedure of all time and is the vision correction procedure of choice for refractive surgeons the world over. LASIK combines the precision of the excimer laser delivery system with the benefit of a sophisticated surgical instrument known as a microkeratome. LASIK eye surgery is performed under anesthetic eye drops. The microtome is used to create a thin corneal flap, which is opened like the page of a book. The excimer laser is then used to sculpt ultra-thin layers of the remaining cornea to change its shape.
By changing the shape of the cornea, treatment of nearsightedness, farsightedness, and/or astigmatism is possible for the appropriate eye. After the laser treatment, the flap is returned back to its original position and adheres without the use of stitches. The entire procedure takes less than 15 minutes for both eyes. There are two types of LASIK eye surgery, Standard LASIK and Custom LASIK (also known as Wavefront-guided LASIK).